OEM/ODM Factory Condensing Unit Out Door - Heat pump water heater 20KW 30KW 40KW 60KW Geothermal ground source Heat Pump – Runte

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

We're committed to furnishing easy,time-saving and money-saving one-stop purchasing support of consumer for Freezer Island, Ice Cream Display Freezer, Walk In Cooler Door, Inspired by the rapid developing market of the fast food and beverage consumables all over the world , We are looking forward to working with partners/clients to make success together.
OEM/ODM Factory Condensing Unit Out Door - Heat pump water heater 20KW 30KW 40KW 60KW Geothermal ground source Heat Pump – Runte Detail:

Parameter

Commercial hot water (1) Commercial hot water (2) Commercial hot water (3) Commercial hot water (4)

Unit Parameter Table
Air-cooled Module Unit Parameter Table      
                                    Unit Type
Unit parameters
ZGR-65ⅡAG2 ZGR-130ⅡAG2
Rated Refrigeration
(A35/W7℃)
Cooling Capacity(kW) 65 130
Power(kW) 20.3 40.6
EER 3.20 3.20
Rated Heating
(A7/W45℃)
Heating Capacity(kW) 70 140
Power(kW) 20.5 41.0
COP 3.41 3.41
Mains 380V/3N~/50Hz
Maximum Operating Current(A) 58 115
Cooling Operating Ambient Temperature Range(℃) 16~49
Heating Operating Ambient Temperature Range(℃)  -15~28
Cooling Water Temperature(℃) 5~25
Heating Water Temperature(℃) 30~50
Refrigerant R410A
Safeguard Higher-lower voltage protection, antifreeze protection, overload, water flow protection, etc.
Capacity Adjustment Method 0~100% 0~50%~100%
Throttling Method Electronic Expansion Valve
Water Side Heat Exchanger Shell and Tube Heat Exchanger
Wind Side Heat Exchanger High-efficiency Finned Tube Heat Exchanger
Fan High Efficiency and Low Noise Axial Flow Fan
Water System Chilled Water Flow(m³/h) 11.2 22.4
Hydraulic Pressure Drop(kpa) 40 75
Maximum Working Pressure(Mpa) 1.0
Water Pipe Connection DN65(Flange) DN80(Flange)
Anti-shock Protection Type Ⅰ
Waterproof Level IPX4
Dimentions Length(mm) 1930 2340
Width(mm) 941 1500
Height(mm) 2135 2350
Weight(kg) 590 1000
Rated refrigeration: outdoor dry/wet bulb temperature is 35°C/24°C; outlet water temperature: 7°C      
Rated heating: outdoor dry/wet bulb temperature is 7℃/6℃; outlet water temperature is: 45℃      
Models, parameters, and performance will be changed due to product improvements. Please refer to the actual product and nameplate for specific parameters;
Executive Standard:GB/T 18430.1(2)-2007 GB/T 25127.1(2)-2010    

Commercial hot water (6) Commercial hot water (7) Commercial hot water (8) Commercial hot water (9) Commercial hot water (10) Commercial hot water (11) Commercial hot water (12) Commercial hot water (13) Commercial hot water (14) Commercial hot water (15) Commercial hot water (16) Commercial hot water (17)


Product detail pictures:

OEM/ODM Factory Condensing Unit Out Door - Heat pump water heater 20KW 30KW 40KW 60KW Geothermal ground source Heat Pump – Runte detail pictures

OEM/ODM Factory Condensing Unit Out Door - Heat pump water heater 20KW 30KW 40KW 60KW Geothermal ground source Heat Pump – Runte detail pictures

OEM/ODM Factory Condensing Unit Out Door - Heat pump water heater 20KW 30KW 40KW 60KW Geothermal ground source Heat Pump – Runte detail pictures

OEM/ODM Factory Condensing Unit Out Door - Heat pump water heater 20KW 30KW 40KW 60KW Geothermal ground source Heat Pump – Runte detail pictures

OEM/ODM Factory Condensing Unit Out Door - Heat pump water heater 20KW 30KW 40KW 60KW Geothermal ground source Heat Pump – Runte detail pictures

OEM/ODM Factory Condensing Unit Out Door - Heat pump water heater 20KW 30KW 40KW 60KW Geothermal ground source Heat Pump – Runte detail pictures

OEM/ODM Factory Condensing Unit Out Door - Heat pump water heater 20KW 30KW 40KW 60KW Geothermal ground source Heat Pump – Runte detail pictures

OEM/ODM Factory Condensing Unit Out Door - Heat pump water heater 20KW 30KW 40KW 60KW Geothermal ground source Heat Pump – Runte detail pictures

OEM/ODM Factory Condensing Unit Out Door - Heat pump water heater 20KW 30KW 40KW 60KW Geothermal ground source Heat Pump – Runte detail pictures

OEM/ODM Factory Condensing Unit Out Door - Heat pump water heater 20KW 30KW 40KW 60KW Geothermal ground source Heat Pump – Runte detail pictures

OEM/ODM Factory Condensing Unit Out Door - Heat pump water heater 20KW 30KW 40KW 60KW Geothermal ground source Heat Pump – Runte detail pictures

OEM/ODM Factory Condensing Unit Out Door - Heat pump water heater 20KW 30KW 40KW 60KW Geothermal ground source Heat Pump – Runte detail pictures

OEM/ODM Factory Condensing Unit Out Door - Heat pump water heater 20KW 30KW 40KW 60KW Geothermal ground source Heat Pump – Runte detail pictures

OEM/ODM Factory Condensing Unit Out Door - Heat pump water heater 20KW 30KW 40KW 60KW Geothermal ground source Heat Pump – Runte detail pictures

OEM/ODM Factory Condensing Unit Out Door - Heat pump water heater 20KW 30KW 40KW 60KW Geothermal ground source Heat Pump – Runte detail pictures


Related Product Guide:

Our solutions are widely regarded and trustworthy by consumers and may meet continually modifying financial and social requirements for OEM/ODM Factory Condensing Unit Out Door - Heat pump water heater 20KW 30KW 40KW 60KW Geothermal ground source Heat Pump – Runte , The product will supply to all over the world, such as: Rio de Janeiro, Myanmar, Mombasa, In the future, we promise to keep offer the high quality and more cost-effective products, the more efficient after sales service to our all customers all over the world for the common development and the higher benefit.
  • The sales person is professional and responsible, warm and polite, we had a pleasant conversation and no language barriers on communication.
    5 Stars By Clementine from Islamabad - 2018.06.05 13:10
    The factory can meet continuously developing economic and market needs, so that their products are widely recognized and trusted, and that's why we chose this company.
    5 Stars By John biddlestone from Tajikistan - 2017.06.29 18:55