Our workforce through professional training. Skilled professional knowledge, solid sense of service, to fulfill the services demands of consumers for Open Condensing Unit, Cold Storage Condensing Unit, Cold Room Refrigeration System, Welcome all prospects of residence and abroad to visit our organization, to forge a outstanding potential by our cooperation.
High reputation R404 Open Type Cold Room Condensing Unit - Monobloc 20KW dc inverter heat pump radiant heating promotion – Runte Detail:

Parameter

commercial heating (1) commercial heating (2) commercial heating (3) commercial heating (4)

Unit Parameter Table
Air-cooled Module Unit Parameter Table
                                    Unit Type
Unit parameters
ZGR-65ⅡAG2 ZGR-130ⅡAG2
Rated Refrigeration
(A35/W7℃)
Cooling Capacity(kW) 65 130
Power(kW) 20.3 40.6
EER 3.20 3.20
Rated Heating
(A7/W45℃)
Heating Capacity(kW) 70 140
Power(kW) 20.5 41.0
COP 3.41 3.41
Mains 380V/3N~/50Hz
Maximum Operating Current(A) 58 115
Cooling Operating Ambient Temperature Range(℃) 16~49
Heating Operating Ambient Temperature Range(℃)  -15~28
Cooling Water Temperature(℃) 5~25
Heating Water Temperature(℃) 30~50
Refrigerant R410A
Safeguard Higher-lower voltage protection, antifreeze protection, overload, water flow protection, etc.
Capacity Adjustment Method 0~100% 0~50%~100%
Throttling Method Electronic Expansion Valve
Water Side Heat Exchanger Shell and Tube Heat Exchanger
Wind Side Heat Exchanger High-efficiency Finned Tube Heat Exchanger
Fan High Efficiency and Low Noise Axial Flow Fan
Water System Chilled Water Flow(m³/h) 11.2 22.4
Hydraulic Pressure Drop(kpa) 40 75
Maximum Working Pressure(Mpa) 1.0
Water Pipe Connection DN65(Flange) DN80(Flange)
Anti-shock Protection Type
Waterproof Level IPX4
Dimentions Length(mm) 1930 2340
Width(mm) 941 1500
Height(mm) 2135 2350
Weight(kg) 590 1000
Rated refrigeration: outdoor dry/wet bulb temperature is 35°C/24°C; outlet water temperature: 7°C
Rated heating: outdoor dry/wet bulb temperature is 7℃/6℃; outlet water temperature is: 45℃
Models, parameters, and performance will be changed due to product improvements. Please refer to the actual product and nameplate for specific parameters;
Executive Standard:GB/T 18430.1(2)-2007 GB/T 25127.1(2)-2010

commercial heating (6) commercial heating (7) commercial heating (8) commercial heating (9) commercial heating (10) commercial heating (11) commercial heating (12) commercial heating (13) commercial heating (14) commercial heating (15) commercial heating (16) commercial heating (17)


Product detail pictures:

High reputation R404 Open Type Cold Room Condensing Unit - Monobloc 20KW dc inverter heat pump radiant heating promotion – Runte detail pictures

High reputation R404 Open Type Cold Room Condensing Unit - Monobloc 20KW dc inverter heat pump radiant heating promotion – Runte detail pictures

High reputation R404 Open Type Cold Room Condensing Unit - Monobloc 20KW dc inverter heat pump radiant heating promotion – Runte detail pictures

High reputation R404 Open Type Cold Room Condensing Unit - Monobloc 20KW dc inverter heat pump radiant heating promotion – Runte detail pictures

High reputation R404 Open Type Cold Room Condensing Unit - Monobloc 20KW dc inverter heat pump radiant heating promotion – Runte detail pictures

High reputation R404 Open Type Cold Room Condensing Unit - Monobloc 20KW dc inverter heat pump radiant heating promotion – Runte detail pictures

High reputation R404 Open Type Cold Room Condensing Unit - Monobloc 20KW dc inverter heat pump radiant heating promotion – Runte detail pictures


Related Product Guide:

We constantly carry out our spirit of ''Innovation bringing advancement, Highly-quality guaranteeing subsistence, Administration selling advantage, Credit rating attracting buyers for High reputation R404 Open Type Cold Room Condensing Unit - Monobloc 20KW dc inverter heat pump radiant heating promotion – Runte , The product will supply to all over the world, such as: Swiss, Chicago, Sacramento, Now, with the development of internet, and the trend of internationalization, we have decided to extend business to overseas market. With the propose of bringing more profits to oversea customers by providing directly abroad. So we have changed our mind, from home to abroad, hope to give our customers more profit, and looking forward to more chance to make business.
  • Managers are visionary, they have the idea of "mutual benefits, continuous improvement and innovation", we have a pleasant conversation and Cooperation.
    5 Stars By Sharon from India - 2018.10.31 10:02
    Timely delivery, strict implementation of the contract provisions of the goods, encountered special circumstances, but also actively cooperate, a trustworthy company!
    5 Stars By Jean Ascher from Sevilla - 2018.08.12 12:27