China Cheap price Cold Room Unit - Heat pump water heater 20KW 30KW 40KW 60KW Geothermal ground source Heat Pump – Runte

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

With our leading technology at the same time as our spirit of innovation,mutual cooperation, benefits and growth, we're going to build a prosperous future together with your esteemed firm for Wine Beverage Cooler, Cold Room For Drinks, Cake Fridge Display, Your inquiry might be extremely welcomed plus a win-win prosperous development are what we've been expecting.
China Cheap price Cold Room Unit - Heat pump water heater 20KW 30KW 40KW 60KW Geothermal ground source Heat Pump – Runte Detail:

Parameter

Commercial hot water (1) Commercial hot water (2) Commercial hot water (3) Commercial hot water (4)

Unit Parameter Table
Air-cooled Module Unit Parameter Table
                                    Unit Type
Unit parameters
ZGR-65ⅡAG2 ZGR-130ⅡAG2
Rated Refrigeration
(A35/W7℃)
Cooling Capacity(kW) 65 130
Power(kW) 20.3 40.6
EER 3.20 3.20
Rated Heating
(A7/W45℃)
Heating Capacity(kW) 70 140
Power(kW) 20.5 41.0
COP 3.41 3.41
Mains 380V/3N~/50Hz
Maximum Operating Current(A) 58 115
Cooling Operating Ambient Temperature Range(℃) 16~49
Heating Operating Ambient Temperature Range(℃)  -15~28
Cooling Water Temperature(℃) 5~25
Heating Water Temperature(℃) 30~50
Refrigerant R410A
Safeguard Higher-lower voltage protection, antifreeze protection, overload, water flow protection, etc.
Capacity Adjustment Method 0~100% 0~50%~100%
Throttling Method Electronic Expansion Valve
Water Side Heat Exchanger Shell and Tube Heat Exchanger
Wind Side Heat Exchanger High-efficiency Finned Tube Heat Exchanger
Fan High Efficiency and Low Noise Axial Flow Fan
Water System Chilled Water Flow(m³/h) 11.2 22.4
Hydraulic Pressure Drop(kpa) 40 75
Maximum Working Pressure(Mpa) 1.0
Water Pipe Connection DN65(Flange) DN80(Flange)
Anti-shock Protection Type
Waterproof Level IPX4
Dimentions Length(mm) 1930 2340
Width(mm) 941 1500
Height(mm) 2135 2350
Weight(kg) 590 1000
Rated refrigeration: outdoor dry/wet bulb temperature is 35°C/24°C; outlet water temperature: 7°C
Rated heating: outdoor dry/wet bulb temperature is 7℃/6℃; outlet water temperature is: 45℃
Models, parameters, and performance will be changed due to product improvements. Please refer to the actual product and nameplate for specific parameters;
Executive Standard:GB/T 18430.1(2)-2007 GB/T 25127.1(2)-2010

Commercial hot water (6) Commercial hot water (7) Commercial hot water (8) Commercial hot water (9) Commercial hot water (10) Commercial hot water (11) Commercial hot water (12) Commercial hot water (13) Commercial hot water (14) Commercial hot water (15) Commercial hot water (16) Commercial hot water (17)


Product detail pictures:

China Cheap price Cold Room Unit - Heat pump water heater 20KW 30KW 40KW 60KW Geothermal ground source Heat Pump – Runte detail pictures

China Cheap price Cold Room Unit - Heat pump water heater 20KW 30KW 40KW 60KW Geothermal ground source Heat Pump – Runte detail pictures

China Cheap price Cold Room Unit - Heat pump water heater 20KW 30KW 40KW 60KW Geothermal ground source Heat Pump – Runte detail pictures

China Cheap price Cold Room Unit - Heat pump water heater 20KW 30KW 40KW 60KW Geothermal ground source Heat Pump – Runte detail pictures

China Cheap price Cold Room Unit - Heat pump water heater 20KW 30KW 40KW 60KW Geothermal ground source Heat Pump – Runte detail pictures

China Cheap price Cold Room Unit - Heat pump water heater 20KW 30KW 40KW 60KW Geothermal ground source Heat Pump – Runte detail pictures

China Cheap price Cold Room Unit - Heat pump water heater 20KW 30KW 40KW 60KW Geothermal ground source Heat Pump – Runte detail pictures

China Cheap price Cold Room Unit - Heat pump water heater 20KW 30KW 40KW 60KW Geothermal ground source Heat Pump – Runte detail pictures

China Cheap price Cold Room Unit - Heat pump water heater 20KW 30KW 40KW 60KW Geothermal ground source Heat Pump – Runte detail pictures

China Cheap price Cold Room Unit - Heat pump water heater 20KW 30KW 40KW 60KW Geothermal ground source Heat Pump – Runte detail pictures

China Cheap price Cold Room Unit - Heat pump water heater 20KW 30KW 40KW 60KW Geothermal ground source Heat Pump – Runte detail pictures

China Cheap price Cold Room Unit - Heat pump water heater 20KW 30KW 40KW 60KW Geothermal ground source Heat Pump – Runte detail pictures

China Cheap price Cold Room Unit - Heat pump water heater 20KW 30KW 40KW 60KW Geothermal ground source Heat Pump – Runte detail pictures

China Cheap price Cold Room Unit - Heat pump water heater 20KW 30KW 40KW 60KW Geothermal ground source Heat Pump – Runte detail pictures

China Cheap price Cold Room Unit - Heat pump water heater 20KW 30KW 40KW 60KW Geothermal ground source Heat Pump – Runte detail pictures


Related Product Guide:

Fast and very good quotations, informed advisers to help you choose the correct merchandise that suits all your preferences, a short creation time, responsible excellent command and different companies for paying and shipping affairs for China Cheap price Cold Room Unit - Heat pump water heater 20KW 30KW 40KW 60KW Geothermal ground source Heat Pump – Runte , The product will supply to all over the world, such as: Jamaica, Dominica, Orlando, With the goal of "zero defect". To care for the environment, and social returns, care employee social responsibility as own duty. We welcome friends from all over the world to visit and guide us so that we can achieve the win-win goal together.
  • Reasonable price, good attitude of consultation, finally we achieve a win-win situation,a happy cooperation!
    5 Stars By Lena from Israel - 2017.09.16 13:44
    This is a reputable company, they have a high level of business management, good quality product and service, every cooperation is assured and delighted!
    5 Stars By Nina from Senegal - 2017.04.18 16:45